Penetration Grade
The penetration test of bitumen quantifies the hardness or softness of bitumen by measuring the depth of penetration of a standard loaded needle in five seconds while maintaining the bitumen sample temperature at 25 °C. The more viscous the bitumen, the less distance needle is able to penetrate. Hence, the penetration value for viscous bitumen is less.
The penetration is measured to specify the bitumen type in accordance with the climatic conditions of the area of bitumen consumption.
This penetration depth is empirically (albeit only roughly) correlated with asphalt binder performance. Therefore, asphalt binders with high penetration numbers (called “soft”) are used for cold climates (for instance, 80/100) while asphalt binders with low pene- tration numbers (called “hard”) are used for warm climates (for instance, 40/50).
Test | Method | 30-40 | 40-50 | 60-70 | 85-100 | 100-120 | 200-300 |
|---|---|---|---|---|---|---|---|
| Specific gravity @25/25C | ASTM D70 | 1/01-1/06 | 1/01-1/06 | 1/01-1/06 | 1/01-1/05 | 1/01-1/04 | 0.99-1/04 |
| Penetration ,25°c,100g5s,min | ASTM D5 | 30-40 | 40-50 | 60-70 | 85-100 | 100-120 | 200-300 |
| Softening point °C | ASTM D-36 | 55-63 | 52-60 | 49-56 | 45-52 | 42-49 | 32min |
| Ductility ,25°c,5cm/min/cm | ASTM D-113 | 100 min | 100 min | 100 min | 100 min | 100 min | 100 min |
| Flash Point °C | ASTM-D92 | 250 min | 250 min | 250 min | 230 min | 250 min | 177min |
| Solubility intrichloroethylene (min %) | ASTM-D2042 | 99.5 min | 99.5 min | 99.5 min | 99.5 min | 99.5 min | 99.0min |
| Spot test | A.A.S.H.T.T102 | Negative | Negative | Negative | Negative | Negative | Negative |
| Drop in penetration afterheating% | ASTM-D5&D6 | 20 max | 20 max | 20 max | 20 max | 20 max | 37min |
| Loss on heating(%wt) | ASTM-D6 | 0.2 max | 0.2 max | 0.2 max | 0.5 max | 0.2 max | 1max |